AFTER SALES DEPARTMENT
TECHNICAL NOTE N° 031
Date : 15/11/10 Revision : 0 Page : 1 of 2
Subject: INOA-TECHNICAL DATAS AND TUBING
Extraction kit: AEVACLM or PEVACLM (not supplied with the air conditioner, option
to be ordered), one kit per hole.
Technical datas: INOA 230 V 50 Hz INOA25 INOA50
Maximum volume of the wine cellar 25 m3 50 m3
Cooling power 600 W 1200 W
Maximum distance for the remote control 10 m 10 m
Quantity of speeds for the condenser fan 4 4
Quantity of speeds of the evaporator fan 3 3
Condenser fan air flow (per speed : 1, 2, 3, 4) in m3/h 230, 335,
431, 563
273, 353,
473, 682
Evaporator fan air flow (per speed : 1, 2, 3) in m3/h 199, 285,
382
227, 352,
445
Gas load in R134a 400 grs 400 grs
Pressures BP and HP for 35°c (in bar) 2,3 ; 11,2 2,1 ; 10,5
Type of gas reducer Capillary Capillary
Condenser gas temperature 47°c 45°c